Understanding the Typical Serum Amyloid A Response Curve: The Key to Interpreting Stablelab® Results.

 By Amy Poulin Braim VMD, DACVS-LA, Senior Veterinarian, Equine Technical Services, Zoetis  

Veterinarians use many types of diagnostics such as a thermometer, stethoscope, ultrasound and radiographs to determine medical conditions in their patients.  What if there was a stall side reliable biomarker test that you could run in 10 minutes to let you know if you had a possible infection? Serum Amyloid A (SAA) is such a marker and can be measured by your horse’s side with Stablelab® during the examination.

Stablelab identifies inflammation due to infection by quantifying the concentration of SAA from a simple blood sample.  SAA is a major acute-phase protein that is produced by a horse’s liver in response to infection; its concentration in the blood can indicate the severity of an infection.  SAA can start to elevate above normal, often before clinical symptoms appear giving the veterinarian an indication to run additional diagnostics and get a jump start on treatment.  Additionally, repeat SAA testing over the course of treatment allows the veterinarian to monitor whether the treatment is effective or not. 1,5

Serum Amyloid A has been shown to be 30 times more sensitive than a thermometer2, more dependable for detecting inflammation caused by infection, monitoring disease progression, and return to health versus traditional lab tests.1 Measuring SAA with Stablelab provides real-time results and is more accurate than traditional laboratory tests like WBC, fibrinogen and A:G at identifying infection in horses.1,3,6

 

The Typical SAA Response Curve is Predictable  

The key to interpreting Stablelab results is a firm understanding of the typical response curve and awareness that a single test result provides important  information, but cannot identify where a horse is in the disease process.

  • A normal, healthy, adult horse will have a SAA level of 0 µg/mL.
  • When a systemic infection is present, SAA levels will rapidly and dramatically rise often into the 100’s or 1000’s mg/mL, while noninfectious inflammatory conditions rarely elevate SAA at all.1-4
  • SAA concentrations will peak within 24-48 hours after infection and will remain elevated until the systemic stimulation is resolved (either by treatment initiated by the veterinarian or the horses own immune response), at which point, SAA concentrations will drop by about 50% every 24 hours.4

Serial Testing is Necessary to Identify Where A Horse is on the Response Curve

By understanding the typical SAA response curve kinetics, serial testing allows for easy interpretation of any result to Detect, Monitor and Screen any patient.  It is important to identify the SAA peak value before one can monitor the timely decline of SAA in response to treatment.

àLet’s consider the following scenario:

A horse with cellulitis was evaluated and initial SAA reading was 485mg/mL.  After initiation of appropriate antimicrobial therapy, the horse was re-evaluated 4 days later and appeared significantly better clinically, but the SAA value is significantly higher 850mg/mL.  How could this be? How can the horse look better, but SAA value is seemingly worse?

àExplanation:

The initial SAA measurement was low on the left side of the curve at the very beginning of disease.  The peak SAA value was missed (likely in the 2000-3000mg/mL range) in the 4-day treatment span from initial examination to follow up.  SAA rose from the initial exam until antimicrobial therapy took effect and now SAA is on the appropriate downward trajectory on the right side of the curve. However, due to sample timing, SAA is higher than the initial baseline value. SAA rises and falls quickly, providing real time results.  Understanding the response curve allows the veterinarian to visualize where those values lay.  To confirm that treatment is working, veterinarians should run an additional test every 24-48 hours to follow the SAA course down to normal.

Real Time Results: Diagnostic Insight on the Spot

No need to send bloodwork to the lab and wait for results. Veterinarians can detect inflammation due to infection, and initiate treatment during the exam without ever leaving the horse’s side. This can save time, money and provides peace of mind to the owner that their horse’s veterinarian has another diagnostic tool to help give the best possible care, and that the horse is on the road to recovery. Tracking SAA concentration in subsequent exams allows the veterinarian to monitor how the horse is responding to treatment, or if a change to the treatment protocol may be indicated.

To learn more about the SAA response curve and incorporating SAA testing with Stablelab into every exam, contact your Zoetis Equine representative today or visit Stablelab.com.

About Zoetis

Zoetis is the leading animal health company, dedicated to supporting its customers and their businesses in advancing care for animals. Building on more than 65 years of experience in animal health, Zoetis discovers, develops, manufactures and commercializes medicines, vaccines, diagnostics, technologies and services, including biodevices, genetic tests and precision livestock farming. Zoetis serves veterinarians, livestock producers and people who raise and care for farm and companion animals with sales of its products in more than 100 countries. In 2020, the company generated annual revenue of $6.7 billion with approximately 11,300 employees. For more information, visit www.zoetis.com.